Isolation : Position of the contacts must be clearly visible or indicated , Inadvertent or unintentional closure shall be prevented , Means to prevent inadvertent or unauthorised opening , Presence for multi pol devices but not excluding adjacent single pole devices , Devices shall be clearly identified by posistion or durable marking to identify the installation or circuit isolates , Switching for Mechanical Maintenance : Must be capable of switching the full line current; it does not need to break the neutral conductor, Should be manually operated, Inadvertent or unintentional switching on shall be prevented, Switching devices to be suitably placed and with durable marking, to be readily identifiable, If a switch, it need not break the neutral conductor, A plug and socket‑outlet not exceeding 16A may be used, Emergency Switching : Must be capable of switching the full load current taking in to account stalled motor current, Should be one switching device or a combination of equipment activated by a single action, Hand‑operated devices preferable and where a circuit breaker or contactor is used, shall operate on de‑energisation, Hand‑operated devices shall be clearly identified preferably by colour (red) and be readily accessible, Shall be latched in the ‘off’ position and re-energisation requires a conscious action by the operator to restore the supply, Shall be placed so as to be readily identifiable and in a convenient position, A plug and socket‑outlet or similar device must not be used, Functional Switching : Functional switching devices shall be suitable for the most onerous duty they are intended to perform, Functional switching devices may control the current without necessarily opening the corresponding poles, Off‑load isolators, fuses and links shall not be used for functional switching, Firefighter's Switching : Shall be easily visible, accessible and marked in a posistion where it can be seen clearly by a person standing on the ground , ON/OFF positions in letters not less than 10mm high ,
0%
Switching
Share
by
S6069167
FE
Electrical
I-edit ang Content
Embed
Uban pa
Assignments
Leaderboard
Show more
Show less
Kini nga leaderboard naka-pribado. Pag-klik sa
Share
aron himuon kini nga publiko.
Kini nga leaderboard gi-disable sa tag-iya sa resource.
Kini nga leaderboard gi-disable tungod ang imong mga kapilian lahi ra sa tag-iya sa resource.
I-revert ang mga Kapilian
Ang
Group sort
usa ka open-ended nga template. Dili kini makamugna ug mga marka sa leaderboard.
Kinahanglan mag log in
Visual style
Fonts
Subscription required
Mga Option
I-switch ang template
Ipakita tanan
Daghang mga format ang mugawas samtang gidula nimo ang activity.
Open results
Copy link
QR code
Mag-delete
I-restore ang gi-autosave:
?